Model

M96

Table size

1100*550 mm

Supply Ability

1000 Sets/Year

Cutting rate

15 m/min

Construction
Design and calculation standards
ISO/TR 15377, ISO 5167, BS 1042, ASME MFC-14M, MFC-3M, DIN 19205, Shell Flow Meter Engineering Handbook
Sizes
DN 10 – DN 100, 3/8” - 4"
Pressure rating
PN 10 - 400, 150 - 2500 lbs
Plate thickness
3 mm
β (d/D)
preferred range 0,5 < β < 0,7 for highest accuracy.
Vent or drain hole
Not recommended
Material
AISI 316, other on request
Pipe run
Can be honed for increased accuracy
Pressure taps
Transmitter flanges with a 54 mm centre distance
Connection
Flanges with flat or raised face or groove according to DIN 2526, 2513 or 2512, or RF and RTJ according to ANSI B 16.5
Orifice plate shapes
Square edge concentric, conical, 1/4 circle, segment
Marking
The carrier rings are marked with "+" and "-" and flow direction
Technical Data
Accuracy
+/- 0,75 - 1 %(square edge plate), +/- 2 %(conical), +/- 2 - 2,5%(¼ circle)
Pressure loss
Depending on β, for β equal to 0,6 : ca. 60 % of the differential pressure measured
Limits for Reynolds No
Re > 1260 x β2 D according to ISO 5167 1000 < Re < 108 according to ASME MFC-14M
Accessories
3 valve manifold, double flanged
Condensing chamber unit for steam flow (only horizontal pipe line)