IRB/1 for RF flanges
IRB/4 for RTJ flanges
Principle: EMCO restriction plates are used to restrict the flow in order to prevent damage on pipe line equipment on the upstream side in blow down systems or to limit the flow / pressure to avoid damage on equipment on the downstream side.
For insertion between compact flanges or clamp connection, ask us.
Design and calculation standards
|
ISO 5167, Shell Flow Meter Engineering Handbook, R.W. Miller: Flow Measurement Engineering Handbook, etc.
|
Sizes
|
1/2" - 24", DN 15 – DN 600
|
Pressure rating
|
150 - 2500 lbs, PN 10 – PN 400
|
Orifice plate shape
|
Square edge concentric
|
Plate thickness
|
thickness is calculated to handle the differential pressure, minimum 3 mm for IRB/1 and 20 mm for IRB/4
|
Material
|
AISI 316, Duplex, Monel, 6Mo, Titanium Hastelloy, Inconel, others on request
|
Mounting style
|
Between Raised Face or Ring Type Joint flanges according to ANSI B16.5 or DIN standards.
|
Handle
|
With name plate in AISI 316 with the following inscription : TAG no., serial no. pressure rating, inner pipe dia., bore, material.
|
Documentation
|
Material certificate acc. to EN 10204-3.1. Noise calculation for gas. Hydro dynamic noise calculation for liquid. If noise level is above acceptable level, Multi hole plate or multi stage pressure reduction is the solution.
|
-
|
-
|
-
|
-
|
-
|
-
|