EPSILON Flow Meter for Insertion Between Flanges

Description

EPSILON is used as primary elements in flow measurement of liquid and gas according to the differential pressure principle. EPSILON flow meter with 5 holes combines a traditional single hole orifice plate with a flow conditioner. This means that straight pipe run up stream the flow meter can be reduced from 20 times inner pipe diameter to 5 times inner pipe diameter, which is crucial with limited space available.

Features


Specifications


Construction

Design and calculation standards
ISO 5167-2, ASME MFC-3M
Sizes
DN 50 - 400, 2" - 16"
Pressure rating
Up to PN 40, 300 lbs, higher pressure ratings on request
Temperature
Process : -50 - +150°C, higher temperature with Remote Mounting Kit
Mounting Style
Between flanges according to DIN or ANSI standards
Flange facing
Flat face, raised face, DIN 2512 N, DIN 2513 R
Overall length
32 mm
Material
Stainless steel AISI 316, other materials on request.
β (d/D) equivalent
0,5 and 0,6


Technical Data

Accuracy
± 1% accuracy
Pressure loss
Typical 150 mbar for liquid flow, and 50 mbar fror gas flow (values are given at full flow)
Rangeability
8:1
Repeatability
better than 0.1%
Limits for Reynolds No
Re > 5000


Accessories

Double flanged 3 or 5 way manifold


Design

Model EP1
The EPSILON flow meter model EP1 consists of a primary element based on the differential pressure principle, a flange manifold for double flanged valve manifold

Model EP2
The EPSILON flow meter model EP2 consists of a primary element based
on the differential pressure principle with an integrated 3 valve manifold

Model EP5
The EPSILON flow meter model EP5 consists of a primary element based
on the differential pressure principle with an integrated 5 valve manifold


Installation Requirements

The EPSILON flow meter can be mounted in a horizontal or vertical pipe. For liquid flow in a horizontal pipe the electronics shall be mounted below the pipe. For gas flow in a horizontal pipe the electronics shall be mounted above the pipe. High accuracy of measurement is achievable even with short straight pipe runs upstream from the flow meter. The required straight pipe run is only 5 x inner pipe diameter and 2 x downstream to maintain an accuracy of 1%. If mass flow is required due to changing process conditions ask for the EPSIMAS mass flow meter data sheet. Saturated and superheated steam is covered by EPSISTEEM flow meters


Additional Images and Drawings