Construction and design of instrumentation since 1966
Monday – Friday

8 am – 4 pm (CET)

+45 45 76 94 00

sales@emco.dk

Høgevej 6

DK-3400 Hillerød

You are here: Home » Products » FLOW » PITOBAR » Pitot Tube for Remote Transmitter Mounting

EMCO PITOBAR Averaging Pitot Tube for remote Transmitter Mounting Type DK200, DK250

Description

The PITOBAR Averaging Pitot Tube is used for flow measurement of liquid and gasses in horizontal or vertical pipe lines. The PITOBAR Averaging Pitot Tube principle of operation is derived from the classic or single point pitot tube. As opposed to the single point pitot tube, the PITOBAR averaging pitot tube has a number of holes depending of pipe size pointing towards the up-stream side. One port pointing down stream measures the static pressure. The PITOBAR has very low installation costs and the pressure loss is low compared to other flow elements, especially in larger pipe sizes.

Features


Specifications


Construction

The PITOBAR Averaging Pitot Tube is constructed and designed with a diamond shaped strut with several ports spaced centrally within concentric rings of equal area pointing towards the upstream side. This is done in order to get the best averaging measurement of the dynamic pressure, resulting in a more
accurate flow reading. 
The pitot tube creates a differential pressure signal which is proportional to the flow rate.
Differential Pressure = ( Pstatic + Pdynamic) – Pstatic.

Design and calculation standards
VDE/VDI 2640, ASME, DIN, EN 13480
Types
DK200 & DK250
Pipe sizes
DK200: 3" - 40" | DK250: 4" - 80"
Probe sizes
DK200: 20 x 20 mm | DK250: 25 x 25 mm
Pressure rating
PN 16 - 400, 150 - 2500 lbs
Temperature range
-100°C - +350 °C
Material PITOBAR
Stainless steel AISI 316, other stainless grades on request
Material mounting part
Carbon steel, stainless steel AISI 316, other on request
Process connection
Flange according to pressure rating
Flange standards
DIN, ANSI
Bottom support
For larger pipe sizes and high velocities
Mounting
Welding to the pipe
Instrument connection
½" BSP or NPT, Weld ends Ø21,3
Mounting neck
Standard lengths, 130, 180, 250 mm, other lenghts available


Technical Data

Accuracy
± 1% accuracy of actual flow
Repeatability
± 0,1%
Reynolds no.
Minimum 100.000 at full flow
Rangeability
10:1
Max. fluid velocity
liquids 5 m/s, gasses 80 m/s


Accessories

Shut-off valves: needle or ball

Required Straight Pipe Lengths

Certain installation requirements for straight pipe lines must be fulfilled in order to achieve the most accurate flow measurement. See table below.

Upstream (x D)
Downstream (x D)
Single 90° bend
9
3
Two or more 90° bends in the same plane
14
3
Two or more 90° bends in in different planes
24
4


Maximum Allowable Differential Pressure

Without bottom support, with reference to mechanical bend. Pressure is measured in bar. See table below. 

Length
DK200 @ 20°C
DK200 @ 400°C
DK250 @ 20°C
DK250 @ 400°C
200
3,75
1,81
300
1,66
0,81
2,52
1,19
400
0,94
0,45
1,42
0,67
500
0,60
0,29
0,91
0,43
600
0,42
0,20
0,63
0,30
700
0,31
0,15
0,46
0,22
800
0,23
0,11
0,35
0,17
1000
0,15
0,07
0,23
0,11

Who to contact?

Christoffer Thrane
Sales & Marketing Manager

(Flow)