You are here: Home » Products » FLOW » Venturis, Cones & Wedge Meters » Venturi Tube » Welded Venturi Tube

EMCO Classical Venturi Tube Type KVR (Welded Sheet)

Description

The classical venturi tube is one of the most tested and trusted flow meters on the market. Based on the ISO 5167-4 standard, it offers durable flow measurement with minimal pressure loss. This welded venturi tube… 

Features


Specifications

Construction

Design and calculation standards

ISO 5167-4, ASME MFC-3M

Sizes

DN 200 - DN 1200

Pressure rating

PN 10 - 100, 150 - 600 lbs, ISO PN 20 - 100

β (d/D)

0,3 < β < 0,75

Material

Carbon steel, AISI 316, other on request

Mounting style

Weld ends according to DN 2559 or ANSI B16.25. Flanges acc. to DIN or ANSI B16.5 standards or clamp connection

Pressure taps

Weld ends Ø 21.3 mm, 26.9 mm, thread connection 3/8", 1/2" BSP, 1/2" NPT

Tappings

Single pressure tappings or 2x4 tappings each arranged with an external annular ring to equalize the pressure

Outlet cone

7-15°


Technical Data

Accuracy

1,5 % (acc. to ISO 5167-4)

Pressure loss

Depending on outlet cone, between 10-15% of the differential pressure measured

Limits for Reynolds No

2*10^5 < ReD < 2*10^6 according to ASME


Accessories

Shut-off valves

Condensing chamber unit for steam flow

Installation

The welded venturi tube must be installed in a straight cylindrical pipe without obstructions, with specific inner pipe diameter requirements. The required straight lengths vary based on beta values and the presence of bends or reducers. Full bore valves are recommended upstream, and the inner pipe wall must be clean and smooth. The Venturi tube should be centered carefully and connected to the differential pressure transmitter below it for most applications, except for gas flow. Safety devices must be in place to prevent pressure exceedance, and elevated temperatures should be avoided. Regular maintenance involves ensuring a deposit-free interior. Compliance with ISO 5167 and other standards is crucial for quality assurance.

Download the installation guide above for more detailed information. 

Who to contact?

Christoffer Thrane
Sales & Marketing Manager

(Flow)

Learn how we calibrate our flow meters

Calibration of a flow meter