![MDP-G1-Main[1]](https://www.emcocontrols.com/wp-content/uploads/2022/05/MDP-G1-Main1.png)
Description
The gas passes each stage at sonic or critical velocity. When the pressure is reduced so is the density of the gas or steam. In order to maintain a constant velocity the cross sectional area is increased after each stage. The calculation is based on R.W. Miller and Ward-smith. Each of the pressure reducing stages are connected and supplied as a unit
EMCO single hole multi stage depressurizing units (SDP-G) are used to reduce the pressure in a number of stages to a desired pressure. EMCO multi hole multi stage depressurizing units (MDP-G) are used to reduce the pressure in a number of stages to a desired pressure and to secure as low noise development as possible
|
|
|
|
Design and calculation standards
|
R.W. Miller: Flow Measurement Engineering Handbook, Ward-Smith ISO 5167 etc.
|
|
Sizes
|
1/2" - 24"
|
|
Pressure rating
|
150 - 2500 lbs,
|
|
Orifice plate shape
|
Square edge concentric
|
|
Plate thickness
|
Thickness is calculated to handle the differential pressure
|
|
Distance between each stage
|
1 - 2 times inner pipe diameter
|
|
Material, plates
|
AISI 316 (standard), and other erosion resistance materials on request
|
|
Material, spool piece
|
P235GH (A106 Gr. B or C), AISI 316, AISI 321, Duplex Hastelloy, other materials on request.
|
|
Mounting style
|
Between flanges according to ANSI B16.5 or DIN Standards or butt weld ends.
|
|
Overall length
|
Depends on number of stages and pipe size. Each multi stage is calculated individually
|
|
Documentation
|
Material certificate acc. to EN 10204-3.1. Noise calculation
|