You are here: Home » Products » FLOW » Orifice Plates » Orifice Plate Series ISB/1 EP for RF Flanges

EMCO Orifice Plate Series ISB/1 EP for RF Flanges

Description

The EMCO Orifice Plate is used as a primary element in flow measurement of liquid, gas and steam applications based on the differential pressure principle. According to this working principle, the orifice plate creates a flow restriction in the pipeline to allow measurement of the resulting pressure drop and flow rate. Our orifice plates have been tested and tried for over 50 years and measure up to the highest industry and compliance standards. 

The Orifice Plate Series ISB/1 EP is especially designed for installations with limited space due to the flow conditioning effect created by the 5 hole design. The design therefore combines a traditional single bore orifice plate with a flow conditioner which can reduce the flow meter from 20 times inner pipe diameter to 5 times inner pipe diameter upstream in a straight pipe run.

Features


Specifications


Construction

Design and calculation standards

ISO 5167, ASME MFC-3M, ASME

Sizes

2” - 24" according to ANSI B 16.36

Pressure rating

300 - 600 lbs RF

Plate thickness

3 - 16 mm depending on plate size

β (d/D)

0,5 - 0,6

Material

AISI 316, 22Cr Duplex 25Cr Duplex, Monel, 6Mo Hastelloy, titanium and others on request

Mounting style

Between raised face flanges according To ANSI B16.36 or DIN 19214, other standards on request

Orifice plate shapes

Square edge

Handle

With name plate in AISI 316 with the following inscription : TAG no., serial no., pressure rating, inner pipe diameter., beta equivalent, material.


Technical Data

Accuracy

+/- 1 %

Pressure loss

Depending on β, for β equal to 0,6 : ca. 60 % of the differential pressure measured

Limits for Reynolds No

Re > 5000

Allowable differential pressure

2,5 bar

Design

Installation

Before installation, the orifice plate must be kept clean and protected against corrosion and physical damage. It is also important that you pay careful attention to to the sharp edge of the plate. Once ensured that it is clean, install the orifice plate carefully such that the orifice bore aligns with the centre of the pipeline. Tap location varies depending on whether it is used for liquid, gas or steam. It is not supplied with any safety devices and must not be used for higher pressure, than stated on the name plate. The pipe system must therefore be equipped with a safety device. However, this type of primary element requires no special maintenance.

Download the installation guide above for more detailed information. 

Who to contact?

Christoffer Thrane
Sales & Marketing Manager

(Flow)

Learn about the important difference between orifice plates and restriction plates